Thermal Solutions >> Fan performance / AMCA 210 Wind Tunnel >> LW-9185

LW-9185 Automatic Air Flow Rate and Pressure Measurement Apparatus

Features
1. Follow AMCA 210 standard Fig.12 & 15 two-in-one structures
2. Automatic system control and data acquisition by PC
3. Accuracy is certificated by credible organization.

Experimental Items
1. Fan or fan tray's PQ performance
2. System Impedance Curve (SRC)
3. Thermal Module's RQ performance

Specifications
1. Air flow rate: 2.9~800 CFM
2. Accuracy of air flow rate: <3.5% INFS
3. Repeatability error: < 2 %
4. Static pressure: 0~30 mmAq
With optional high static pressure throttle device, it can reach 200 mmAq.
5. Overall dimension: 1.8 (W) × 4.6 (L) × 1.9 (H) m (Ref.)
6. Operation space: 2.8 (W) × 6 (L) × 2.2 (H) m (Ref.)
7. Power source: AC220V, 20 Amp, 3 phase, 50/60Hz


Technical Information
Download Catalogue


LW-9185 AMCA 210 Wind Tunnel


High static pressure throttle device
High static pressure throttle device (Optional)
PC control throttle device, area resolution 1/5000
Suitable for testing both high-static or normal fans.
No influence on wind tunnel accuracy.


LW-9240 Multi fan electric performance test device
LW-9240 Multi fan electric performance test device (Optional)
3 unit per set, for measuring voltage, current and RPM of fans
Power source for fans: through external power supply (DC 0~30V & 0~3A).