Thermal Solutions >> Fan performance / AMCA 210 Wind Tunnel >> LW-9185
LW-9185 Automatic Air Flow Rate and Pressure Measurement Apparatus
Features
1. Follow AMCA 210 standard Fig.12 & 15 two-in-one structures
2. Automatic system control and data acquisition by PC
3. Accuracy is certificated by credible organization.
Experimental Items
1. Fan or fan tray's PQ performance
2. System Impedance Curve (SRC)
3. Thermal Module's RQ performance
Specifications
1. Air flow rate: 2.9~800 CFM
2. Accuracy of air flow rate: <3.5% INFS
3. Repeatability error: < 2 %
4. Static pressure: 0~30 mmAq
With optional high static pressure throttle device, it can reach 200 mmAq.
5. Overall dimension: 1.8 (W) × 4.6 (L) × 1.9 (H) m (Ref.)
6. Operation space: 2.8 (W) × 6 (L) × 2.2 (H) m (Ref.)
7. Power source: AC220V, 20 Amp, 3 phase, 50/60Hz
Technical Information
| Download Catalogue |
High static pressure throttle device (Optional)
PC control throttle device, area resolution 1/5000
Suitable for testing both high-static or normal fans.
No influence on wind tunnel accuracy.
LW-9240 Multi fan electric performance test device (Optional)
3 unit per set, for measuring voltage, current and RPM of fans
Power source for fans: through external power supply (DC 0~30V & 0~3A).