AMCA Series

Thermal Test

Environmental Test

Flow Visualization

LW-9300T Thermal Wind Tunnel

1. horizontal & blow down open-circuit structure

2. test section dimension :

  2.1 300¡]W¡^¡Ñ 300¡]H¡^¡Ñ 1000¡]L¡^mm

  2.2 outlet dimension : 300¡Ñ150 mm, adjustable range : 150~15 mm

  2.3 outlet dimension : 225¡Ñ150 mm, adjustable range : 150~15 mm

  2.4 outlet dimension : 150¡Ñ150 mm, adjustable range : 150~15 mm

3. wind speed range :

  3.1 while heating state : 0.2~5 m/sec

  3.2 no heating state : 0.2~8 m/sec

4. the flow field quality of test section :

  under ambient temperature, on 80¢H test section area from the center,

  and up to 2 m/sec or higher wind speed :

  4.1 non-uniform ¡Õ 2¢H

  4.2 turbulence intensity ¡Õ 2¢H

  Under heating environment, there is a complicated relationship between

  Temperature field and speed field.

  Thus, we don¡¦t describe the qualities of speed uniform, turbulence

  intensity, and temperature uniform.

5. contraction area ratio : 6.25 : 1

6. temperature control : ambient temperature 25¢J ~ 70¢J, or ¡µt ¡× 45¢J

7. smoke generator : wind speed range : 2~8 m/sec

8. laser sheet device : 30 mW laser, wavelength 532 nm

9. speed measurement : 0 ~ 6.35 mmAq pressure transducer, with Pitot static

     tube to measure wind speed

     pressure transducer accuracy : 0.25 ¢H

     wind speed range : 1 ~ 10 m/sec

10. overall dimension : 0.9¡]W¡^¡Ñ 6¡]L¡^¡Ñ 1.5¡]H¡^m