AMCA Series

Thermal Test

Environmental Test

Flow Visualization

LW-9300 Open-circuit Subsonic Wind Tunnel

1. test section : 300 x 300 x 1000 mm (L)

2. contraction ratio : 9:1

3. power : 12Hp

4. axial fan

5. smoke generator system

6. wind speed : 1 - 40 m/sec

7. non-uniform : < 0.5%

8. turbulence intensity : < 0.5%

9. purposes: drag, lift, Cd, boundary layer &

    distribution of pressure measurement, etc