AMCA Series

Thermal Test

Environmental Test

Flow Visualization

LW-9014N Air Flow Rate and Pressure Measurement Apparatus

1. Flow rate : 0.19 ~ 10.8 CFM

2. Using rectangular structure which can raise 1.27 times effectiveness.

3. Power source : AC220V, 5Amp, single phase

4. Wind tunnel dimension: 0.6 (D) ¡Ñ 3.0 (L) ¡Ñ 1.6 (H) m

5. Operation space: 1.8 (D) ¡Ñ 4.0 (L) ¡Ñ 2.2 (H) m

6. Functions : PQ test for fan or fan tray

                       Impedance test for components or system

                       Active air flow rate generator

7. Features : Both upper stream and down stream, 2 test environments.

                      The whole system is fully PC-based controlled.