AMCA Series

Thermal Test

Environmental Test

Flow Visualization

LW-9009 Multi-Point & Color Dye Generator

1. Dye output point :12 points, 4 points / 1 dye container

2. Dye container : 3 pcs, each volume: 400 C.C.

3. Switches of output points are controlled by solenoid valve,

    which can be operated by manual, or I/O control of PC or PLC.

4. Static pressure generator,

    pressure-generating range : 0 - 2000 mmAq

    including pressure adjusting and indicating device.

5. Throttle valve for adjusting the output volume of dye.

6. Dimension of output tube : 1.67 (OD) x 1.37 (ID) x 15 (L) mm

7. Power source : AC110V / 220V

¡@

¡@

¡@

¡@

¡@

¡@

¡@

¡@

¡@

¡@