AMCA Series

Thermal Test

Environmental Test

Flow Visualization

LW-9002 Water Tunnel for Force Measurement &  Flow Visualization

Range of Reynolds number :100 to 100,000

Models can be changed easily, changing a set of model will be less than

one minute. Current designed and tested model items are more than 100 varieties.

1. Test section : 30 (D) x 200 (W) x 300 (H) mm

2. Force measurement : 0.1 to 500 gf

3. Flow velocity :1 to 200 cm/sec.

4. Lifting force, drag and shearing force may be measured.

5. Standard streamlines : 40

6. Measurement device for each weight unit :8000 to 20000 N/m^3

7. Viscosity measurement device

8. Controlled temperature : Celsius 5 to 50 degrees